Auto-Push me HL7 (ADT) se X-ray software ko naam kaise bheje?

Web: Imaging Bridge → Auto-Push → "HL7 (ADT)" dabao (toast "✓ HL7 mode — enter IP and port below"). "Where to send HL7" box me "X-ray PC IP", "Port", "Software name (MSH-5)", "Message" (A04 — new patient / A08 — update / A28 — add person) bharo → "Save". Phir X-ray PC par Test Push.

Where in ORALZY: Setup → Integrations → Imaging Bridge (ORALINK)

HL7 me naam aur DOB bina encryption ke jaate hain, isliye ORALZY sirf clinic ke apne network (192.168.x.x / 10.x.x.x / 172.16–31.x.x) ya usi PC par bhejta hai — bahar ka address apne aap block. Host me sirf IP ya naam likho, http:// ya path nahi (warna error "Enter only an IP or hostname…"). "Wait for confirmation (ACK) from the software" default ON hai — OFF karoge to pata nahi chalega patient pahuncha ya nahi; sirf tab band karo jab dealer bole software ACK nahi bhejta. IP / port / MSH-5 / message ya ACK wala tick badalte hi Test Push dobara chahiye. Mobile par sirf "HL7 (ADT)" preset aur bheji ja rahi IP dikhti hai — IP / port web par bharo.

Quick steps

  1. Auto-Push me "HL7 (ADT)" dabao
  2. "X-ray PC IP", "Port", "Software name (MSH-5)" bharo
  3. "Message" me A04 / A08 / A28 chuno → "Save"
  4. "Wait for confirmation (ACK)" ON rehne do
  5. X-ray PC par Test Push chalao